NEW QUESTION # 59
An administrator needs to set up a RAID of at least 4 disks that can sustain the failure of only one disk and is cost effective.
Which RAID level fulfills these requirements?
- A. RAID 5
- B. RAID 0
- C. RAID 6
- D. RAID 10
Answer: A
NEW QUESTION # 60
Which log can be viewed in the iDRAC?
- A. Lifecycle Log
- B. Error Log
- C. Security Log
- D. Application Log
Answer: A
NEW QUESTION # 61
On a Microsoft Windows Server 2016 with Hyper-V, what is a prerequisite to support the host and run virtual machines at the same time?
- A. Host firewall disabled
- B. Hypervisor joined to a cluster
- C. 4 GB of memory
- D. Dual CPU configuration
Answer: C
NEW QUESTION # 62
What is an accurate statement in reference to software RAID?
- A. Software RAID requires a hardware license
- B. Software RAID is an additional cost
- C. Software RAID uses CPU resources
- D. Software RAID does not have any data integrity issues
Answer: C
NEW QUESTION # 63
What is the amount of hard drives request per RAID set, when configure RAID 50?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION # 64
A company is planning a physical security solution for its branches worldwide.
Which danger are they trying to avoid?
- A. Ransomware
- B. Asset vandalism
- C. Phishing
- D. Buffer Overflow
Answer: B
NEW QUESTION # 65
What is an accurate statement regarding 40 Gbps Ethernet ports?
- A. Can be used as a single 40 Gb connector or used as four 10 Gb connections
- B. Must be segmented into four independent 10 Gb connections
- C. May only be used as a non-negotiable, single 40 Gb link
- D. Cannot be configured into a stack connection
Answer: A
NEW QUESTION # 66
A server administrator needs to change the settings of their iDRAC utilizing just the front panel.
Which configuration would allow this?
- A. LED with Quick Sync 2
- B. Both LCD and LED
- C. LED Only
- D. LCD Only
Answer: D
NEW QUESTION # 67
Which type of drive is an array of semiconductor memory organized as a disk drive that uses an integrated circuit?
- A. SATA
- B. SAS
- C. SSD
- D. PATA
Answer: C
NEW QUESTION # 68
What is the name of the log generated by SupportAssist?
- A. Technical Support Log
- B. Support Assist Report
- C. Technical Support Report
- D. Support Assist Log
Answer: C
NEW QUESTION # 69
What is the primary reason for a server emitting a greater heat load than a client system?
- A. Smaller system fans in the server
- B. Increased power usage of the server components
- C. Less space for air to circulate inside the server chassis
- D. Higher ambient temperature in the data center
Answer: B
NEW QUESTION # 70
A customer requires a solution that allows data in RAM to be retained in case of power loss.
Which technology should be used?
- A. NVMe
- B. DDR DIMM
- C. SDRAM
- D. NVDIMM
Answer: D
NEW QUESTION # 71
Which Ethernet cable type should be installed if high interference is a concern?
- A. UTP
- B. 802.11n
- C. RJ45
- D. STP
Answer: D
NEW QUESTION # 72
A system administrator needs to set up a server and assign an IP address on a Class C network. All addresses are available on the network.
Which IP address should the system administrator use for the server?
- A. 195.0.0.0
- B. 200.200.200.255
- C. 192.168.12.0
- D. 210.100.155.12
Answer: D
NEW QUESTION # 73
What are systems management activities conducted by Dell EMC PowerEdge administrators?
- A. Segment system networks to ensure security of the environment, and keep traffic from causing bottlenecks
- B. Manage licensing compliance on a single cluster, to keep compliance with software vendors around the globe
- C. Manage standalone systems individually on a one-to-one interface, ensuring individualized configuration for each system and isolating it from other servers
- D. Create, deploy, and replicate template-based configurations optimized for workload performance as well as manage multiple systems from a single workstation
Answer: D
NEW QUESTION # 74
An administrator wishes to create a complex RAID set for a high-performance database, where the value of the data far exceeds the cost of the drives.
Which complex RAID level should be used?
- A. RAID 1
- B. RAID 10
- C. RAID 60
- D. RAID 50
Answer: B
NEW QUESTION # 75
What is s backup process?
- A. Capturing historical records used for further reference and is not actively used by the server
- B. Moving data that is no longer activity used to a separate storage device, for long-term retention
- C. Copying files to a secondary site for preservation in case of equipment failure of other catastrophe
- D. Using server technologies to transmit data from one computer node to another
Answer: C
NEW QUESTION # 76
Which software agent installed on a Dell EMC PowerEdge server allows technical support to gather the Operating System information with SupportAssist collection?
- A. SAE
- B. iSM
- C. SRS
- D. OMSA
Answer: B
NEW QUESTION # 77
Which service is provided by a Dell EMC Smart Uninterruptible Power Supply (UPS)?
- A. Increased wattage to the power supplies of the server
- B. Limited standby power in the event of a power outage
- C. Remote maintenance of any attached server
- D. Uninterrupted power during a prolonged power outage
Answer: B
NEW QUESTION # 78
......
Try Free and Start Using Realistic Verified D-PE-FN-23 Dumps Instantly.: https://braindumps2go.dumpstorrent.com/D-PE-FN-23-exam-prep.html